Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Addiction ; 113(11): 2099-2106, 2018 11.
Artigo em Inglês | MEDLINE | ID: mdl-29920842

RESUMO

AIMS: To measure carbonyl emissions from a heated tobacco product (IQOS) in comparison with an e-cigarette (Nautilus Mini) and a commercial tobacco cigarette (Marlboro Red). DESIGN: Regular and menthol variants of the heated tobacco product were tested. A tank-type atomizer was tested with a tobacco-flavoured liquid at 10 and 14 W. Aerosol and smoke were collected in impingers containing 2,4-dinitrophenylhydrazine. Health Canada Intense and two more intense puffing regimens were used. SETTING: Analytical laboratory in Greece. MEASUREMENTS: Carbonyl levels in the aerosol and smoke. FINDINGS: At the Health Canada Intense regimen, heated tobacco products emitted 5.0-6.4 µg/stick formaldehyde, 144.1-176.7 µg/stick acetaldehyde, 10.4-10.8 µg/stick acrolein, 11.0-12.8 µg/stick propionaldehyde and 1.9-2.0 µg/stick crotonaldehyde. Compared with the tobacco cigarette, levels were on average 91.6% lower for formaldehyde, 84.9% lower for acetaldehyde, 90.6% lower for acrolein, 89.0% lower for propionaldehyde and 95.3% lower for crotonaldehyde. The e-cigarette emitted 0.5-1.0 µg/12 puffs formaldehyde, 0.8-1.5 µg/12 puffs acetaldehyde and 0.3-0.4 µg/12 puffs acrolein, but no propionaldehyde and crotonaldehyde. At more intense puffing regimens, formaldehyde was increased in heated tobacco products, but levels were three-fourfold lower compared with the tobacco cigarette. Based on the findings from Health Canada Intense puffing regimen, use of 20 heated tobacco sticks would result in approximately 85% to 95% reduced carbonyl exposure compared with smoking 20 tobacco cigarettes; the respective reduction in exposure from use of 5 g e-cigarette liquid would be 97% to > 99%. CONCLUSIONS: The IQOS heated tobacco product emits substantially lower levels of carbonyls than a commercial tobacco cigarette (Marlboro Red) but higher levels than a Nautilus Mini e-cigarette.


Assuntos
Aerossóis/análise , Sistemas Eletrônicos de Liberação de Nicotina , Nicotiana/química , Fumaça/análise , Produtos do Tabaco/análise , Acetaldeído , Acroleína , Aerossóis/química , Aldeídos , Formaldeído , Humanos
2.
Nicotine Tob Res ; 20(8): 1004-1009, 2018 07 09.
Artigo em Inglês | MEDLINE | ID: mdl-28637344

RESUMO

Introduction: The purpose was to measure nicotine levels to the tobacco and levels emitted to the aerosol of a heat-not-burn product (HnB, IQOS) compared to e-cigarettes (ECs) and a tobacco cigarette. Methods: The HnB device and regular and menthol sticks were purchased from Italy. Three types of ECs (ciga-like, eGo-style, and variable wattage) and a commercially-available tobacco cigarette were also tested. A custom-made liquid containing 2% nicotine was used with ECs. Products were tested using Health Canada Intense puffing regime while HnB and ECs were additionally tested using a 4-second puff duration regime while maintaining the same puff volume. Results: Nicotine content in HnB regular and menthol tobacco sticks was 15.2 ± 1.1 mg/g and 15.6 ± 1.7 mg/g tobacco respectively. The levels of nicotine to the aerosol were similar for regular and menthol HnB products (1.40 ± 0.16 and 1.38 ± 0.11 mg/12 puffs respectively) and did not change significantly with prolonged puff duration. The tobacco cigarette delivered the highest level of nicotine (1.99 ± 0.20 mg/cigarette), with levels being higher than HnB and ECs under Health Canada Intense regime but similar to eGo-style and variable wattage ECs at prolonged puff duration regime. Conclusions: The HnB product delivers nicotine to the aerosol at levels higher than ECs but lower than a tobacco cigarette when tested using Health Canada Intense puffing regime. No change in HnB nicotine delivery was observed at prolonged puff duration with the same puff volume, unlike ECs which deliver more nicotine with longer puff duration. Implications: Nicotine delivery to the smoker is expected to play an important role in the ability of any harm-reduction product to successfully substitute smoking. This study evaluated the content and nicotine delivery to the aerosol of a heat-not-burn tobacco product (IQOS) in comparison with e-cigarettes and a tobacco cigarette. The main findings were that the heat-not-burn tobacco sticks contained similar nicotine concentration to tobacco cigarettes, and that the levels of nicotine delivered to the aerosol of the heat-not-burn products were lower than tobacco cigarette, higher than e-cigarettes at low puff duration but lower than high-power e-cigarettes at longer puff duration.


Assuntos
Aerossóis/análise , Sistemas Eletrônicos de Liberação de Nicotina/métodos , Temperatura Alta , Nicotina/análise , Produtos do Tabaco/análise , Aerossóis/administração & dosagem , Sistemas Eletrônicos de Liberação de Nicotina/instrumentação , Redução do Dano , Humanos , Nicotina/administração & dosagem
3.
Addiction ; 111(6): 1069-76, 2016 06.
Artigo em Inglês | MEDLINE | ID: mdl-26756124

RESUMO

AIMS: To propose a protocol and evaluate the consistency in nicotine delivery to the aerosol of different types of electronic cigarette (EC) atomizers, as required by regulatory authorities. DESIGN: Three cartomizer and four tank-type atomizer products were tested (three samples per product). The aerosol from three 20-puff sessions from each sample was collected using a smoke machine. Three cartridges from a nicotine inhaler and three tobacco cigarettes were also tested. SETTING: Analytical laboratory in Greece. MEASUREMENTS: Aerosol nicotine levels were measured. Relative standard deviation (RSD, i.e. coefficient of variation) was calculated separately for each cartomizer and replacement atomizer head sample (intrasample RSD) and between different samples (intersample RSD). The percentage difference from the mean, which is used to assess the quality of medicinal nebulizers, was also calculated. FINDINGS: The aerosol nicotine levels were 1.01-10.61 mg/20 puffs for ECs, 0.12-0.18 mg/20 puffs for the nicotine inhaler and 1.76-2.20 mg/cigarette for the tobacco cigarettes. The intrasample RSDs were 3.7-12.5% for ECs and 14.3% for the nicotine inhaler and 11.1% for the tobacco cigarettes. The intersample RSDs were higher in cartomizers (range: 6.9-37.8%) compared with tank systems (range: 6.4-9.3%). All tank-type atomizers and one cartomizer were within 75-125% of the mean, as dictated for medicinal nebulizers. CONCLUSIONS: Electronic cigarettes that use tank-type atomizers appear to deliver nicotine in more consistent quantities (within the acceptable limits for medicinal nebulizers and similar to the nicotine inhaler) than electronic cigarettes that use cartomizers. The protocol for testing nicotine delivery consistency described in this paper could be used effectively for regulatory purposes.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina/normas , Nicotina/administração & dosagem , Agonistas Nicotínicos/administração & dosagem , Política Pública/legislação & jurisprudência , Aerossóis , Desenho de Equipamento , Grécia , Humanos , Produtos do Tabaco/normas
4.
Eukaryot Cell ; 10(3): 412-22, 2011 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-21169416

RESUMO

Eukaryotic phosphoinositide-specific phospholipases C (PI-PLC) specifically hydrolyze phosphatidylinositol 4,5-bisphosphate [PtdIns(4,5)P(2)], produce the Ca(2+)-mobilizing agent inositol 1,4,5-trisphosphate, and regulate signaling in multicellular organisms. Bacterial PtdIns-specific PLCs, also present in trypanosomes, hydrolyze PtdIns and glycosyl-PtdIns, and they are considered important virulence factors. All unicellular eukaryotes studied so far contain a single PI-PLC-like gene. In this report, we show that ciliates are an exception, since we provide evidence that Tetrahymena species contain two sets of functional genes coding for both bacterial and eukaryotic PLCs. Biochemical characterization revealed two PLC activities that differ in their phosphoinositide substrate utilization, subcellular localization, secretion to extracellular space, and sensitivity to Ca(2+). One of these activities was identified as a typical membrane-associated PI-PLC activated by low-micromolar Ca(2+), modestly activated by GTPγS in vitro, and inhibited by the compound U73122 [1-(6-{[17ß-3-methoxyestra-1,3,5(10)-trien-17-yl]amino}hexyl)-1H-pyrrole-2,5-dione]. Importantly, inhibition of PI-PLC in vivo resulted in rapid upregulation of PtdIns(4,5)P(2) levels, suggesting its functional importance in regulating phosphoinositide turnover in Tetrahymena. By in silico and molecular analysis, we identified two PLC genes that exhibit significant similarity to bacterial but not trypanosomal PLC genes and three eukaryotic PI-PLC genes, one of which is a novel inactive PLC similar to proteins identified only in metazoa. Comparative studies of expression patterns and PI-PLC activities in three T. thermophila strains showed a correlation between expression levels and activity, suggesting that the three eukaryotic PI-PLC genes are functionally nonredundant. Our findings imply the presence of a conserved and elaborate PI-PLC-Ins(1,4,5)P(3)-Ca(2+) regulatory axis in ciliates.


Assuntos
Regulação Enzimológica da Expressão Gênica , Fosfoinositídeo Fosfolipase C/genética , Fosfoinositídeo Fosfolipase C/metabolismo , Tetrahymena/enzimologia , Sequência de Aminoácidos , Dados de Sequência Molecular , Fosfatidilinositóis/metabolismo , Fosfoinositídeo Fosfolipase C/química , Filogenia , Alinhamento de Sequência , Tetrahymena/química , Tetrahymena/classificação , Tetrahymena/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...